Low-toxic fire-resistant cables used for single or group stationary installation in fire protection systems, fire and security alarm systems, evacuation alert and control systems, communication networks, and data collection and transmission systems. Suitable for installation in kindergartens, educational institutions, nursing homes, hospitals, and dormitory buildings. Operates at voltages up to 300 V with 180 minutes of fire resistance under open flame conditions.
• Range of operating temperatures: -40…+70 °С.
• Range of laying and installation temperatures: -15…+50 °С.
• Bending radius – not less than 10 times the value of the outer diameter of the cable.
• Minimum service life is 25 years.
• They are used for indoor and outdoor installations, provided they are protected from solar radiation (categories 2-4 according to GOST 15150-69)
• Fire hazard class (according to GOST R 31565-2012): PRGP 1b (category A) – limit of fire propagation in group installation; PO 1 (up to 180 min.) – limit of fire resistance under flame exposure conditions; PTPM 1 (more than 120 g/m3) – toxicity equivalent of materials combustion products; PD 2 (more than 50%) – heat generation ability index during combustion and smoldering.
Construction:
• Conductors: single-wire copper conductors
• Cross-section of cores: 0,2 — 2,5 mm2
• Insulation: fire-resistant silicone rubber compound
• Twisting: in pairs
• Screen: laminated aluminum foil with a contact conductor made of tinned copper wire
• Sheath: PVC plastic compound of reduced fire hazard with low smoke and gas emission
• Colors of insulated conductors: red-black, blue-brown, white-brown, pink-green
• Number of pairs in cable: 1 — 4
• White sheath
Article
Product name
Boil, m
4547
KPSEng(А)-FRLSLTx 1х2х0,2
200
4548
KPSEng(А)-FRLSLTx 2х2х0,2
200
4551
KPSEng(А)-FRLSLTx 1х2х0,35
200
4552
KPSEng(А)-FRLSLTx 2х2х0,35
200
4543
KPSEng(А)-FRLSLTx 1х2х0,5
200
4555
KPSEng(А)-FRLSLTx 2х2х0,5
200
4560
KPSEng(А)-FRLSLTx 1х2х0,75
200
4561
KPSEng(А)-FRLSLTx 2х2х0,75
200
4565
KPSEng(А)-FRLSLTx 1х2х1
200
4566
KPSEng(А)-FRLSLTx 2х2х1
200
4569
KPSEng(А)-FRLSLTx 1х2х1,5
200
4570
KPSEng(А)-FRLSLTx 2х2х1,5
200
4573
KPSEng(А)-FRLSLTx 1х2х2,5
200
4574
KPSEng(А)-FRLSLTx 2х2х2,5
200
48911
KPSEng(А)-FRLSLTx 4х2х0,5
200
48912
KPSEng(А)-FRLSLTx 4х2х0,75
200
4547-50
KPSEng(А)-FRLSLTx 1х2х0,2
50
4548-50
KPSEng(А)-FRLSLTx 2х2х0,2
50
4551-50
KPSEng(А)-FRLSLTx 1х2х0,35
50
4552-50
KPSEng(А)-FRLSLTx 2х2х0,35
50
4543-50
KPSEng(А)-FRLSLTx 1х2х0,5
50
4555-50
KPSEng(А)-FRLSLTx 2х2х0,5
50
4560-50
KPSEng(А)-FRLSLTx 1х2х0,75
50
4561-50
KPSEng(А)-FRLSLTx 2х2х0,75
50
4565-50
KPSEng(А)-FRLSLTx 1х2х1
50
4566-50
KPSEng(А)-FRLSLTx 2х2х1
50
4569-50
KPSEng(А)-FRLSLTx 1х2х1,5
50
4570-50
KPSEng(А)-FRLSLTx 2х2х1,5
50
4573-50
KPSEng(А)-FRLSLTx 1х2х2,5
50
4574-50
KPSEng(А)-FRLSLTx 2х2х2,5
50
48911-50
KPSEng(А)-FRLSLTx 4х2х0,5
50
48912-50
KPSEng(А)-FRLSLTx 4х2х0,75
50
01 /
Request a callback
thank you for leaving a request
thank you for leaving a request
We use cookies. By continuing to browse our website, you acknowledge that you have read and agree to the terms of our «Privacy Policy»
and consent to the processing of personal data by analytics programs